Core Service

Fire Fighting Systems

Hydrant, wet riser, sprinkler and fire pump systems. We design, supply, install, test and commission them for buildings of every scale.

→

→

Fire Fighting Systems

Overview

Fire Fighting Systems from Fire Remedy Systems

Fire fighting is our flagship specialisation. We handle complete water-based fire protection, from single-storey government offices to multi-storey hospital complexes and industrial facilities.

A fire fighting system only works if every part works together: storage tanks, the pump room, the pipe network, and the hydrants, landing valves and sprinkler heads at the end of it. We take responsibility for the whole chain, so what we hand over is a system that has been tested end to end.

Every installation complies with the National Building Construction Standards 2026, CPWD specifications and Bureau of Indian Standards requirements, using materials from approved vendors.

Scope of Work

What We Deliver

Fire Hydrant Systems

External yard hydrants on a ring main around the building, for fire brigade and on-site firefighting.

Wet Riser Systems

Vertical pipes kept charged with water, with landing valves on every floor of tall buildings.

Automatic Sprinkler Systems

Heat-activated sprinkler heads that control a fire at its source, zone by zone.

Water Mist Systems

Fine water droplets for spaces where conventional sprinklers would cause excessive water damage.

Electric Motor Driven Pumps

Main fire pumps that start automatically when system pressure drops.

Diesel Engine Driven Pumps

Standby pumps that keep the system running if mains power fails.

Jockey Pumps

Small pumps that hold system pressure and make up for minor leakage.

Hose Reel Systems

First-aid firefighting hose reels for occupants to tackle a fire early.

Ring Main Pipelines

Looped underground and external pipework that feeds hydrants from more than one direction.

Portable Fire Extinguishers

Selection, supply and placement of extinguishers to suit each risk class.

How We Work

Our Process

01

Survey & Design

Site survey, load and hazard assessment, and design to the applicable codes.

02

Supply

Materials and equipment sourced from approved vendors to CPWD and BIS specifications.

03

Installation

Execution by trained site teams under qualified engineering supervision.

04

Testing & Commissioning

Every system tested end to end before handover.

05

Handover & Support

As-built documentation, client training, and ongoing AMC support.

Compliance

Standards We Follow

NBCS 2026, Part F

Fire and Life Safety: decides which systems a building needs based on its height and occupancy.

IS 3844

Installation and maintenance of internal fire hydrants and hose reels.

IS 13039

External hydrant systems.

IS 15105

Design and installation of fixed automatic sprinkler systems.

IS 2190

Selection, installation and maintenance of portable fire extinguishers.

CPWD Specifications

Materials, workmanship and testing for government works.

Track Record

Notable Projects

Fire Fighting System at NSEZ, Noida

NBCC Ltd.

Wet Riser & Sprinkler System at Canara Bank, BKC Mumbai

CPWD

Fire Fighting System at NIT Calicut Mega Hostel

CPWD Palakkad

Sectors We Serve

Government Buildings

Healthcare & Hospitals

Educational Institutions

Commercial & Corporate

Defence & PSU

Residential Townships

FAQs

Common Questions

It depends on your building’s height, area and occupancy type under the National Building Construction Standards. Most buildings need some combination of hydrants, wet risers, sprinklers, fire pumps and extinguishers. We survey your site and confirm exactly what the code requires, so you install what is needed, no less and no more.
Yes. We prepare the layouts, hydraulic calculations and specifications for the Fire NOC submission, and support the fire department’s inspection until the certificate is issued.
Yes. A meaningful share of our work is taking over incomplete or non-compliant installations, such as the fire fighting repair at the UPSC campus, Dholpur House, and the wet riser renovation at the MP Residences on BKS Marg, both for CPWD. We survey what exists, fix what is missing, and test and commission the system.
We source from approved vendors. Before any order is placed, technical data sheets for every major item, such as pumps, valves and sprinklers, are sent to you for approval, so you know exactly what is being installed.
We test and commission the system, hand over the documentation, and can maintain it afterwards under an annual maintenance contract, so it stays ready for inspections.
From single-building retrofits to large campuses. Recent work includes the fire fighting system at the Noida SEZ for NBCC, wet risers and sprinklers at Canara Bank, BKC, and the fire fighting system for the 1,500-capacity NIT Calicut Mega Hostel.

Need a fire fighting system designed, installed or upgraded?

Our team is ready to evaluate your requirements and propose the right solution.

Contact Us →