Fire fighting contractor · Kozhikode, Kerala
Fire Fighting Contractor in Calicut
Fire Remedy Systems (FRS) designs, installs and maintains fire hydrant, wet riser, sprinkler and fire pump systems for buildings in Calicut (Kozhikode). FRS installed the fire fighting system for the 1,500-capacity Mega Hostel at NIT Calicut, for CPWD Palakkad.
Since 1983
CPWD Class-1 (Composite)
ISO 9001:2015
600+ projects
Home → Services → Fire Fighting Systems → Calicut
At a glance
FRS in Calicut: key facts
Projects in Calicut
NIT Calicut Mega Hostel: fire fighting system for a 1,500-capacity hostel, for CPWD Palakkad
Other projects in Kerala
STPI Office Building, Technopark, Thiruvananthapuram; Cochin Special Economic Zone, Kochi
Systems we install
Hydrants, wet risers, sprinklers, fire pump rooms, fire alarm and detection, public address
Maintenance
Annual maintenance contracts, including systems installed by other contractors
Fire authority
Kerala Fire and Rescue Services
Governing law
Kerala Municipality Building Rules, 2019 (fire NOC table re-issued October 2025)
Owner's recurring duty
Final NOC renewed every year, or for up to five years at a time (two for hazardous buildings)
Company
Fire Remedy Systems (FRS), head office New Delhi, established 1983
Enlistment
CPWD Class-1 (Composite), tenders up to ₹50 crore; ISO 9001:2015
Enquiries
Information on this page was checked on 17 November 2026.
Track record
Our projects in Kerala
Education
NIT Calicut Mega Hostel
Kozhikode
Fire fighting system for the 1,500-capacity hostel.
Client: CPWD Palakkad
SEZ
Cochin Special Economic Zone (CSEZ)
Kakkanad, Kochi
Fire safety and ECM works.
Client: Cochin SEZ Authority
Commercial
STPI Office Building, Technopark
Thiruvananthapuram
Balance civil and interior works, with fire, electrical, ELV, HVAC, solar and STP under a single contract.
Client: STPI
More of our projects are listed on our Clients page.
Services
What FRS installs in Calicut buildings
Wet risers bring water to a landing valve on every floor. Yard hydrants on a ring main serve the fire brigade at ground level. FRS installed the fire fighting system for the NIT Calicut Mega Hostel.
Each sprinkler head opens on its own when it reaches its rated temperature, so only the heads above a fire discharge water.
An electric main pump, a diesel standby pump and a jockey pump that keeps the system pressurised. The main pumps start automatically when pressure falls.
Addressable detectors and manual call points report to a panel that shows the exact device in alarm, with public address and voice evacuation.
Survey and repair of systems that are not working, then scheduled inspection and testing of pumps, valves, sprinklers and alarm panels, with service records after every visit.
Getting started
How to get a quote
Send us
✓
The building’s address and use (housing, offices, hospital, hotel, warehouse)
✓
Height and number of floors, including basements
✓
Built-up area
✓
Drawings, and the tender or BOQ if you have one
✓
Where you are: new building, fire NOC pending, or an existing system that needs repair or AMC
What happens next
1
An FRS engineer surveys the site and checks the drawings against the fire approval conditions.
2
You receive an itemised quotation.
3
Before anything is ordered, we send you data sheets for the pumps, valves, sprinklers and panels for approval.
4
A project manager and engineers stay on site for the installation and send weekly progress reports.
5
We test and commission each system, then hand over the drawings and records.
FAQs
Questions from Calicut building owners
Sources for the fire approval answers
Kerala Municipality Building Rules, 2019 (Kerala Fire and Rescue Services NOC portal)
Kerala Municipality Building (Amendment) Rules, 2025 (LSGD building permit portal)
Kerala Fire and Rescue Services: NOC portal
Kerala Fire and Rescue Services: NOC FAQs
Kerala Fire and Rescue Services: NOC procedures
Onmanorama: fire NOC validity extended to five years (August 2025)
Onmanorama: final fire NOC needed before occupancy (November 2026)
Rules change. Confirm the current position with the fire authority before you apply. Last checked: 17 November 2026.
Planning a fire fighting system for a building in Calicut?
Send your drawings or a short description of the building. We will arrange a site survey and an itemised quotation.
Get a quote →