Fire fighting contractor · Delhi
Fire Fighting Contractor in Delhi
Fire Remedy Systems (FRS) designs, installs and maintains fire hydrant, wet riser, sprinkler and fire alarm systems. FRS was established in New Delhi in 1983 and its head office is here. Its Delhi work includes fire fighting and fire alarm works at Parliament House Annexe and fire safety works at North Block, both for CPWD.
Since 1983
CPWD Class-1 (Composite)
ISO 9001:2015
600+ projects
Home → Services → Fire Fighting Systems → Delhi
At a glance
FRS in Delhi: key facts
Head office
New Delhi (established 1983)
Area covered
All of Delhi
Projects in Delhi
12 listed below, including Parliament House Annexe, North Block, Delhi High Court, CAPFIMS and the Lok Sabha Residential Complex
Clients in Delhi
CPWD, DDA, LIC, IFCI, All India Radio, L&T Construction
Systems we install
Hydrants, wet risers, sprinklers, fire pump rooms, fire alarm and detection, public address
Maintenance
Annual maintenance contracts, including systems installed by other contractors
Fire authority
Delhi Fire Service, Government of NCT of Delhi
Governing law
Delhi Fire Service Act, 2007 and Delhi Fire Service Rules, 2010 (amended May 2026)
Owner's recurring duty
Yearly declaration that the fire systems work; renewal every 3 years (5 for residential buildings other than hotels), applied for 6 months before expiry
Enlistment
CPWD Class-1 (Composite), tenders up to ₹50 crore; ISO 9001:2015
Enquiries
Information on this page was checked on 17 November 2026.
Track record
Our fire safety projects in Delhi
Project
Scope
Client
Parliament House Annexe
Government · New Delhi
Fire fighting and fire alarm works.
CPWD
North Block
Government · New Delhi
Fire safety works in a live heritage ministry building.
CPWD
Soochna Bhawan
Government · New Delhi
Fire detection, fire fighting and public address as one package.
All India Radio / CPWD
Delhi High Court
Government · New Delhi
Fire safety works.
CPWD
UPSC Campus, Dholpur House
Government · New Delhi
Fire fighting system repair and rectification.
CPWD
CAPFIMS
Healthcare · Maidan Garhi, New Delhi
Addressable fire alarm system; internal and external electrical works.
L&T Construction
SSKH & LHMC
Healthcare · New Delhi
Fire safety works in a working hospital.
CPWD
Jeevan Bharti
Commercial · New Delhi
Fire safety works.
LIC
MP Residences, BKS Marg
Residential · New Delhi
Wet riser renovation.
CPWD
Vasant Kunj Apartments
Residential · New Delhi
Fire safety works.
DDA
Lok Sabha Residential Complex
Residential · New Delhi
Fire alarm system replacement.
CPWD
Service Apartments, Mayur Vihar
Residential · New Delhi
Plumbing and fire fighting.
IFCI
Work outside Delhi, including HAL Tumkur and the STPI Office Building at Technopark, is listed on our Clients page.
Services
What FRS installs in Delhi buildings
Wet risers bring water to a landing valve on every floor. Yard hydrants on a ring main serve the fire brigade at ground level. FRS renovated the wet riser system at the MP Residences on BKS Marg.
Each sprinkler head opens on its own when it reaches its rated temperature, so only the heads above a fire discharge water.
An electric main pump, a diesel standby pump and a jockey pump that keeps the system pressurised. The main pumps start automatically when pressure falls.
Addressable detectors and manual call points report to a panel that shows the exact device in alarm, with public address and voice evacuation. FRS installed an addressable system at CAPFIMS and replaced the alarm system at the Lok Sabha Residential Complex.
Survey and repair of systems that are not working, then scheduled inspection and testing of pumps, valves, sprinklers and alarm panels, with service records after every visit. At the UPSC campus, Dholpur House, FRS repaired and rectified the existing fire fighting system.
Getting started
How to get a quote
Send us
✓
The building’s address and use (housing, offices, hospital, hotel, warehouse)
✓
Height and number of floors, including basements
✓
Built-up area
✓
Drawings, and the tender or BOQ if you have one
✓
Where you are: new building, fire NOC pending, or an existing system that needs repair or AMC
What happens next
1
An FRS engineer surveys the site and checks the drawings against the fire approval conditions.
2
You receive an itemised quotation.
3
Before anything is ordered, we send you data sheets for the pumps, valves, sprinklers and panels for approval.
4
A project manager and engineers stay on site for the installation and send weekly progress reports.
5
We test and commission each system, then hand over the drawings and records.
FAQs
Questions from Delhi building owners
Sources for the fire approval answers
Delhi Fire Service Act, 2007 (Delhi Fire Service)
Delhi Fire Service Rules, 2010 (Delhi Fire Service)
Delhi Fire Service: renewal of Fire Safety Certificate
Delhi Gazette, 26 May 2026: Delhi Fire Service (Amendment) Rules, 2025
Delhi Gazette, 17 October 2026: auditor provisions deferred to 20 May 2027
Bar & Bench: Delhi High Court notice on private fire auditors (September 2026)
Rules change. Confirm the current position with the fire authority before you apply. Last checked: 17 November 2026.
Planning a fire fighting system for a building in Delhi?
Send your drawings or a short description of the building. We will arrange a site survey and an itemised quotation.
Get a quote →