Fire fighting contractor · Delhi

Fire Fighting Contractor in Delhi

Fire Remedy Systems (FRS) designs, installs and maintains fire hydrant, wet riser, sprinkler and fire alarm systems. FRS was established in New Delhi in 1983 and its head office is here. Its Delhi work includes fire fighting and fire alarm works at Parliament House Annexe and fire safety works at North Block, both for CPWD.

Since 1983

CPWD Class-1 (Composite)

ISO 9001:2015

600+ projects

Home → Services → Fire Fighting Systems → Delhi

At a glance

FRS in Delhi: key facts

Head office

New Delhi (established 1983)

Area covered

All of Delhi

Projects in Delhi

12 listed below, including Parliament House Annexe, North Block, Delhi High Court, CAPFIMS and the Lok Sabha Residential Complex

Clients in Delhi

CPWD, DDA, LIC, IFCI, All India Radio, L&T Construction

Systems we install

Hydrants, wet risers, sprinklers, fire pump rooms, fire alarm and detection, public address

Maintenance

Annual maintenance contracts, including systems installed by other contractors

Fire authority

Delhi Fire Service, Government of NCT of Delhi

Governing law

Delhi Fire Service Act, 2007 and Delhi Fire Service Rules, 2010 (amended May 2026)

Owner's recurring duty

Yearly declaration that the fire systems work; renewal every 3 years (5 for residential buildings other than hotels), applied for 6 months before expiry

Enlistment

CPWD Class-1 (Composite), tenders up to ₹50 crore; ISO 9001:2015

Enquiries

[email protected]

Information on this page was checked on 17 November 2026.

Track record

Our fire safety projects in Delhi

Project

Scope

Client

Parliament House Annexe

Government · New Delhi

Fire fighting and fire alarm works.

CPWD

North Block

Government · New Delhi

Fire safety works in a live heritage ministry building.

CPWD

Soochna Bhawan

Government · New Delhi

Fire detection, fire fighting and public address as one package.

All India Radio / CPWD

Delhi High Court

Government · New Delhi

Fire safety works.

CPWD

UPSC Campus, Dholpur House

Government · New Delhi

Fire fighting system repair and rectification.

CPWD

CAPFIMS

Healthcare · Maidan Garhi, New Delhi

Addressable fire alarm system; internal and external electrical works.

L&T Construction

SSKH & LHMC

Healthcare · New Delhi

Fire safety works in a working hospital.

CPWD

Jeevan Bharti

Commercial · New Delhi

Fire safety works.

LIC

MP Residences, BKS Marg

Residential · New Delhi

Wet riser renovation.

CPWD

Vasant Kunj Apartments

Residential · New Delhi

Fire safety works.

DDA

Lok Sabha Residential Complex

Residential · New Delhi

Fire alarm system replacement.

CPWD

Service Apartments, Mayur Vihar

Residential · New Delhi

Plumbing and fire fighting.

IFCI

Work outside Delhi, including HAL Tumkur and the STPI Office Building at Technopark, is listed on our Clients page.

Services

What FRS installs in Delhi buildings

Wet risers and hydrants

Wet risers bring water to a landing valve on every floor. Yard hydrants on a ring main serve the fire brigade at ground level. FRS renovated the wet riser system at the MP Residences on BKS Marg.

Automatic sprinklers

Each sprinkler head opens on its own when it reaches its rated temperature, so only the heads above a fire discharge water.

Fire pump rooms

An electric main pump, a diesel standby pump and a jockey pump that keeps the system pressurised. The main pumps start automatically when pressure falls.

Fire alarm and detection

Addressable detectors and manual call points report to a panel that shows the exact device in alarm, with public address and voice evacuation. FRS installed an addressable system at CAPFIMS and replaced the alarm system at the Lok Sabha Residential Complex.

Repair and maintenance (AMC)

Survey and repair of systems that are not working, then scheduled inspection and testing of pumps, valves, sprinklers and alarm panels, with service records after every visit. At the UPSC campus, Dholpur House, FRS repaired and rectified the existing fire fighting system.

Getting started

How to get a quote

Send us

✓

The building’s address and use (housing, offices, hospital, hotel, warehouse)

✓

Height and number of floors, including basements

✓

Built-up area

✓

Drawings, and the tender or BOQ if you have one

✓

Where you are: new building, fire NOC pending, or an existing system that needs repair or AMC

Send your requirement

What happens next

1

An FRS engineer surveys the site and checks the drawings against the fire approval conditions.

2

You receive an itemised quotation.

3

Before anything is ordered, we send you data sheets for the pumps, valves, sprinklers and panels for approval.

4

A project manager and engineers stay on site for the installation and send weekly progress reports.

5

We test and commission each system, then hand over the drawings and records.

FAQs

Questions from Delhi building owners

It does if it is on the Delhi Fire Service list (Rule 27, rewritten in May 2026): residential buildings over 15 m or with five or more storeys; hotels and guest houses over 12 m or four or more storeys; educational, institutional and mercantile buildings over 9 m or three or more storeys; business buildings over 15 m or five or more storeys; all assembly buildings; industrial and storage buildings over 250 sq m of covered area; hazardous buildings over 100 sq m; and underground structures of two or more levels. Stilt and mezzanine floors above ground count as storeys.
The Delhi Fire Service, under the Delhi Fire Service Act, 2007 and Rules, 2010, across all of Delhi including the NDMC area of New Delhi. The document is called a Fire Safety Certificate. For a new building, the body that sanctions the plan, such as MCD, NDMC or DDA, refers it to the fire service; renewal applications are made online, and the Delhi Fire Service website links the portal.
At the plan stage the fire service sets the fire safety measures the design must include, and these stay valid unless the plan is revised. The contractor installs the systems to those measures, tests them and hands over as-built drawings, equipment data sheets and testing and commissioning records. The owner then applies for the Fire Safety Certificate, and fire officers inspect the building before granting or refusing it.
Five years for residential buildings other than hotels and three years for other buildings, with renewal due at least six months before expiry and a declaration every year that the fire systems work. Rules notified in May 2026 would let empanelled private auditors certify buildings and replace the fixed term with a yearly online declaration; they have been put off until 20 May 2027, and the Delhi High Court has issued notice on a challenge to them.
Yes. Most of FRS’s work is in occupied buildings, including the Parliament House Annexe, North Block, the Delhi High Court and CAPFIMS hospital. We phase the work and use out-of-hours windows where needed, so the building keeps running.
Yes. For CPWD, FRS repaired and rectified the fire fighting system at the UPSC campus, Dholpur House, and renovated the wet riser at the MP Residences on BKS Marg. Work starts with a survey of what is installed and what is missing; FRS then quotes for the repairs and an annual maintenance contract, with service records after every visit for the yearly declaration and renewal.
Yes. Most of FRS’s Delhi work is for government bodies such as CPWD and DDA, but clients also include LIC (Jeevan Bharti), IFCI (service apartments at Mayur Vihar) and L&T Construction (CAPFIMS).
FRS was established in New Delhi in 1983 and its head office is in New Delhi. Delhi projects are run from the head office, and a senior executive from head office checks the quality of every project, independently of the site team.

Planning a fire fighting system for a building in Delhi?

Send your drawings or a short description of the building. We will arrange a site survey and an itemised quotation.

Get a quote →