Fire fighting contractor · Noida, Uttar Pradesh
Fire Fighting Contractor in Noida
Fire Remedy Systems (FRS) designs, installs and maintains fire hydrant, wet riser, sprinkler and fire pump systems for buildings in Noida and Greater Noida. FRS installed the fire fighting system at the Noida Special Economic Zone (NSEZ) for NBCC.
Since 1983
CPWD Class-1 (Composite)
ISO 9001:2015
600+ projects
Home → Services → Fire Fighting Systems → Noida
At a glance
FRS in Noida: key facts
Projects in Noida
Noida Special Economic Zone (NSEZ): fire fighting system, for NBCC
Other projects in Uttar Pradesh
Institute of Medical Sciences BHU, Banaras Hindu University and Kendriya Vidyalaya DLW, all in Varanasi, for CPWD
Systems we install
Hydrants, wet risers, sprinklers, fire pump rooms, fire alarm and detection, public address
Maintenance
Annual maintenance contracts, including systems installed by other contractors
Fire authority
Uttar Pradesh Fire and Emergency Services (Gautam Buddh Nagar district for most buildings)
Governing law
Uttar Pradesh Fire and Emergency Services Act, 2022 and Rules, 2024
Owner's recurring duty
Maintenance declaration every January and July, certified by a licensed agency; renewal applied for one month before expiry
Company
Fire Remedy Systems (FRS), head office New Delhi, established 1983
Enlistment
CPWD Class-1 (Composite), tenders up to ₹50 crore; ISO 9001:2015
Enquiries
Information on this page was checked on 17 November 2026.
Track record
Our projects in Noida and the region
SEZ
Noida Special Economic Zone (NSEZ)
Noida
Fire fighting system.
Client: NBCC Ltd.
Healthcare
CAPFIMS
Maidan Garhi, New Delhi
Addressable fire alarm system; internal and external electrical works.
Client: L&T Construction
Healthcare
Institute of Medical Sciences, BHU
Varanasi
Wet riser and drinking water pump system.
Client: CPWD
More of our projects are listed on our Clients page.
Services
What FRS installs in Noida buildings
Wet risers bring water to a landing valve on every floor. Yard hydrants on a ring main serve the fire brigade at ground level. FRS installed the fire fighting system at NSEZ.
Each sprinkler head opens on its own when it reaches its rated temperature, so only the heads above a fire discharge water.
An electric main pump, a diesel standby pump and a jockey pump that keeps the system pressurised. The main pumps start automatically when pressure falls.
Addressable detectors and manual call points report to a panel that shows the exact device in alarm, with public address and voice evacuation.
Survey and repair of systems that are not working, then scheduled inspection and testing of pumps, valves, sprinklers and alarm panels, with service records after every visit.
Getting started
How to get a quote
Send us
✓
The building’s address and use (housing, offices, hospital, hotel, warehouse)
✓
Height and number of floors, including basements
✓
Built-up area
✓
Drawings, and the tender or BOQ if you have one
✓
Where you are: new building, fire NOC pending, or an existing system that needs repair or AMC
What happens next
1
An FRS engineer surveys the site and checks the drawings against the fire approval conditions.
2
You receive an itemised quotation.
3
Before anything is ordered, we send you data sheets for the pumps, valves, sprinklers and panels for approval.
4
A project manager and engineers stay on site for the installation and send weekly progress reports.
5
We test and commission each system, then hand over the drawings and records.
FAQs
Questions from Noida building owners
Sources for the fire approval answers
Uttar Pradesh Fire and Emergency Services Act, 2022 (gazette copy, PRS Legislative Research)
Uttar Pradesh Fire and Emergency Services Rules, 2024 (UP Fire and Emergency Services)
UP Fire and Emergency Services: officers list
Nivesh Mitra: single-window services
Rules change. Confirm the current position with the fire authority before you apply. Last checked: 17 November 2026.
Planning a fire fighting system for a building in Noida?
Send your drawings or a short description of the building. We will arrange a site survey and an itemised quotation.
Get a quote →